Requirements
To begin, make sure you have the following equipment:
A compatible Bimba stepper motor.
Asmallatbladescrewdriverfortighteningtheconnectors(included).
AsuitableDCpowersupply.BimbarecommendsthePWR-150A24orPWR-320A48availablefromBimba.
Wiring the Drive
Step 1 - Wiring the DC Supply
Step 2 - Wiring the Motor
DRV-4/-8 Quick Start Guide
Quick Start Guide
Connectthedrivetothemotor.Fourleadmotorscanbeconnectedinonlyoneway,asshowninFigure1.
Werecommendthateightleadmotorsbeconnectedinparallel,asshowninFigure2.
Ifusinganon-Bimbamotor,pleaserefertoyourmotorspecsforwiringinformation.
red
blue
yellow
white
A+ A- B+ B-
orange+blk/wht
black+org/wht
red+yel/wht
yellow+red/wht
A+ A- B+ B-
Figure 1 Figure 2
Motor & Power Supply
Connector
Run Current, Idle Current
Steps/rev, Inertia, Self Test
Input & Output
Signals
Motor Selector
Status LEDs
Layout of the front panel of the DRV drive.
a)WirethedrivetotheDCpowersource.
DONOTapplypoweruntilallconnectionstothedrivehavebeenmade
DONOTalteranyrotaryordipswitchsettingsofthedrivewhilepoweris
applied.Thiscancausepermanentdamagetothedrive.
b)Note,theDRV4acceptsDCvoltagesfrom24-48V,whiletheDRV8accepts
DCvoltagesfrom24-75V.
Ensureaproperearthgroundconnectionbyusingthescrewontheleftside
of the chassis.
Ifusinganexternalfuse,werecommendthefollowingin-linewiththeV+connection:
DRV4:3AG,4amp(Littlefuse313004P)
DRV8:3AG,6.25amp(Littlefuse3136.25P)
*SeetheOLEManualformoreinformationaboutpowersupplyandfuseselection.
Page view 0
1 2

Summary of Contents

Page 1 - DRV-4/-8 Quick Start Guide

RequirementsTo begin, make sure you have the following equipment: • A compatible Bimba stepper motor. • Asmallatbladescrewdriverfortightening

Page 2 - Setting up the Drive

CONTENTSForm QSG-DRV-4/8-031BBimba Manufacturing Company P.O. Box 68 Monee, Illinois 60449-0068 Phone: 708-534-8544 Toll Free: 800-44-BIMBA Fax:

Related models: DRV-4

Comments to this Manuals

No comments